Manual Telescopic Doors Manufacturers Turnkey India Delhi Gurgaon
EASA ELEVATORS PRIVATE LIMITED
We help our customers strike balance between today’s challenges and tomorrow’s opportunities…… and we do the same for ourselves.
With over a decade of experience in installing special purpose custom designed elevators, Freight elevators, Dumb Waiters and Passenger elevators. We at Easa® are ready for any challenges in the vertical transportation sector.
At EASA® we have a modern manufacturing facility at Manesar, Gurgaon. The activities cover, design on German designer software’s comprising of exhaustive dimension and 3D images of all types of elevators, calculation for precise implementation of design & execution on shop floor through experience and appropriate machines.
We lead through innovation and strong outsourcing. Most critical parts like Microprocessor controllers, safety devices, automatic doors and drives are imported from leading manufactures all over the world.
Flexibility
The small civil dimensions result in saving immense space in each and every project. More so we can design elevators to fit into any shafts built already. We could also provide elevators fitted in steel and glass structures outside or within the buildings.
Every project is monitored by our engineers and we interact with your architects and consultants with detailed drawings and 3D presentations.
Direct Installation of Elevators.
The installation of EASA® elevators is undertaken by specialized technicians trained by us and who work exclusively for us.
Codes & By-laws
We respect the codes and by-laws of the lift authority and ensure that the lifts are fitted as per IS specifications in force.
Safety
We ensure that the best safety equipments are fitted and tested at each and every site for reliability and performance.
Maintenance
EASA® offers comprehensive maintenance contract which is reasonably priced and we undertake to maintain the equipment and attend to the call back services.
Standard Features:
Emergency car lighting
An emergency light switches on automatically in the event of a power failure, providing illumination within the car. The emergency light will allow any passengers inside the car to utilize the interphone or the alarm bell to alert the building superintendent.
Full collective operation
This facility provides for the landing and car calls to be recorded in a logical sequence according to the direction of the car travel. This system handles the inter-floor traffic very well and is suited for most application
Attendant service
In attendant service, if the Close Door Button is released before the doors are closed, the doors will reopen. The car will start immediately after the doors have been closed.
Fire emergency return.
When the building’s fire or smoke detectors are activated, all calls are cancelled and all the elevators will immediately travel to the main lobby or a pre-designated floor and park there with the door fully open. However the electrical signal that indicates the actuation of the fire sensors must be supplied to the elevator controller by others or the fire alarm switch provided on ground floor be activated.
Car light & fan automatically shut off
Elevators can be installed with an energy saving feature that automatically switches off the car internal lighting and ventilation fans when no calls are registered after a predetermined (programmable) period of time.
Interphone ( only for Passenger lifts)
In case of emergencies, the interphone installed inside the car can direct communication with rescue personnel in the motor room or car top. The interphone is activated by simply pressing the interphone button on the car operation panel.
Variable Voltage Variable frequency drive
(For passenger elevator).
This facilitates soft start, soft stopping and good ride quality. In addition to facilitating good control of the elevator this system facilitates high energy savings i.e. low consumption of power and improves the life of the mechanical systems and brakes extensively.
Fault information recorded.
20 last fault information’s are recorded to check what happened during a break down.
Lifts with Automatic Doors.
• Door protective device
It is a multi-beam light ray type door protective device, which surveys the car entrance. When a passenger or an object passes the entrance, the elevator will stop the doors at the point of contact and re-open the car doors immediately.
• Door holding time.
The door open time can be programmed and the time delay set in the system.
• The lift can be designed to go out of service if the doors are kept open for a long time.
• A delay to the start the lift after the doors are closed (say 0.2 to 2.0 sec) can be programmed.
• Choice for doors to reopen when the landing floor button is pressed. This mode can be deactivated for commercial buildings.
Over speed protection (Down direction)
It can ensure the car’s running speed in normal range In case of the car starts traveling faster than its rated speed. The governor activates the emergency safety brakes fitted in the car.
Arrival chime
An electronic chime provides an audio signal to inform waiting passengers of the arrival of the elevator car at each floor. The chime can be mounted on the top or bottom of the car.
Emergency Alarm
A battery operated alarm bell is provided to allow passenger to alert the building superintendent.
Maximum Call Registration
Limit Maximum car calls to be registered at one time to avoid misuse, improve traffic efficiency and avoid redundant stopping of the car.
Parking Floors
To improve efficiency and save time the elevator car can be programmed to return to a predetermined floor after remaining idle. The idle time can also be programmed.





